Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Product Details
Customization: Available
Certification: ISO, CE
Disinfection: Disinfection
Still deciding? Get samples of US$ 200/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 13485, FSC
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
  • Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
Find Similar Products

Basic Info.

Model NO.
TY-LP foot
Color
Silver
Application
Small Bone
Material
Pure Titanium
Properties
Implant Materials & Artificial Organs
Instrument Classification
Class III
Warranty
One Year
After-Sale Service
Online Technical Support
Package
Sterile/Non-Sterile Package
Certificate
CE/ISO 13485
OEM
Accepted
Transport Package
Carton
Specification
TA3
Origin
Jiangsu, China
HS Code
902110
Production Capacity
500 Piece/Pieces Per Month

Product Description

Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

The Structure Of The Foot

The structure of the foot is roughly divided into three parts, that is, the front foot, the middle foot, and the rear foot. It should be noted that the structures and functions of these three parts are different.

 

Foot bones include 7 tarsal bones, 5 metatarsal bones, and 14 phalanges. A total of 26 pieces.


The calcaneus is the most common site of tarsal fractures, accounting for approximately 60% of all tarsal fractures in adults. The incidence is highest in young men. Most calcaneal fractures are occupational injuries caused by axial forces from a fall. Most are displaced intra-articular fractures (60%-75%). One study reported that among 752 calcaneal fractures that occurred over a 10-year period, the annual incidence of calcaneal fractures was 11.5 per 100,000 population, with a male-to-female ratio of 2.4:1. 72% of these fractures were caused by falls.
 

Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate IIICalcaneal Locking Plate III
Excellent anatomic pre-shaped design, no need to bend in operation.
The edge with arched surface design, low-profile and reduce the irritation to the soft tissue.
The closed circular structure provide stable support for the comminuted fracture.
The top hole aim sustentaculum tali can support the joint surface.


 

Treatment principles

- Based on biomechanical and clinical research, the reduction and fixation of calcaneal fractures should meet the following requirements.

- Reduction, anatomical reduction for fractures involving articular surfaces.

- Restore the overall shape and length, width and height geometric parameters of the calcaneus.

- Restoring the flattening of the subtalar articular surface and the normal anatomical relationship between the three articular surfaces.

- Restore the weight-bearing axis of the hind foot.



Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
Calcaneal Locking Plate IV
Low profile design can reduce the irritation to the soft tissue -easy to shape and cut in the operation.
Three holes aims the sustentaculum talus to provide excellent support to the talocalcaneal joint surface.
The flexible part provide extra support to the anterior and plantar bone.

Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Calcaneus Protrusion Locking Plate

Code: 251518XXX

Screw Size: HC3.5


Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Combined Calcaneal Locking Plate

Code: 251516XXX

Screw Size: HC3.5

Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Posterior Calcaneal Tuberosity Locking Plate

Code: 251517XXX

Screw Size: HC3.5


Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Cubiodeum Locking Plate

Code: 251519XXX

The cuboid is a short bone with a total of 1 in each foot. The cuboid is the only bone in the midfoot that supports the lateral column of the foot. It is located between the fourth and fifth metatarsal bones and the calcaneus. It is the basic structure that forms the lateral longitudinal arch of the foot. The stabilization of the lateral column plays an important role and participates in all natural movements of the foot.

Cuboid fractures are uncommon and can be divided into avulsion fractures and compression fractures, caused by direct or indirect violence. Cuboid avulsion fractures are mostly caused by varus, but varus can also cause compression fractures.

Classification of midfoot fractures: Type I is avulsion fractures; Type II is split fractures; Type III is compression fractures involving a single joint; Type IV is compression fractures involving both articular surfaces.


Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
 

Navicular Locking Plate

Code: 251520XXX

The navicular is a small bone in the wrist joint. The navicular bone is close to the radial side of the row, and its shape is like a boat, hence its name. But irregular, the back is long and narrow, rough and uneven, forming a joint with the radius. When a fall is injured, the palm is on the ground, and the navicular bone bears the brunt, and is compressed between the radius and the capitus, resulting in a fracture.

Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Talus Neck Locking Plate

Code: 251521XXX

The neck of the talus is the narrow part between the head and the body of the talus. Rough above, deep talar groove below

Talus neck fractures are uncommon in clinical work, and routine X-ray examinations are often easy to miss the diagnosis, and CT examination and three-dimensional reconstruction scanning need to be further improved to confirm the diagnosis.


Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate IIIX-Type Locking Plate
- High universality,applied for foot fracture, osteotomy, arthrodesis.
- Edge low-profile design to reduce the irritation to the soft tissue.
- Easy shaped to fit the bone surface.
- Compressed guide pin hole with temporary fixation.
- With Large medial, small and super small size for choice.


 

Calcaneal Locking Plate
Name and Screw Code Specification W/mm T/mm L/mm
Calcaneal Locking Plate III
HC 3.5
251514011 Large, L / 2 71.9
251514012 Large, R / 2 71.9
251514021 Medial, L / 2 66.5
251514022 Medial, R / 2 66.5
251514031 Small, L / 2 59.7
251514032 Small, R / 2 59.7

Combined Calcaneal Locking Plate
HC 3.5
251516011 Small, L 10 1.8 57.4
251516012 Small, R 10 1.8 57.4
251516021 Medial, L 10 1.8 59.4
251516022 Medial, R  10 1.8 59.4
251516031 Large, L 10 1.8 68.9
251516032 Large, R 10 1.8 68.9
 Posterior Calcaneal Tuberosity Locking Plate
HC 3.5
251517011 Small, L 10 1.8 40.2
251517012 Small, R 10 1.8 40.2
251517021 Large, L 10 1.8 47.8
251517022 Large, R 10 1.8 47.8
Calcaneus Protrusion Locking Plate
HC 3.5
251518011 Small, L 10 1.8 42.8
251518012 Small, R 10 1.8 42.8
251518021 Large, L 10 1.8 47.8
251518022 Large, R 10 1.8 47.8
Calcaneal Locking Plate IV
IV
HC 3.5
251515011 15Holes, L (L=64) / 2 64.3
251515012 15Holes, R (L=64) / 2 64.3
251515021 15Holes, L (L=69) / 2 69.3
251515022 15Holes, R (L=69) / 2 69.3
251515031 15Holes, L (L=76) / 2 76.3
251515032 15Holes, R (L=76) / 2 76.3
Cubiodeum Locking Plate
HC 2.4/2.7
251519111 11Holes,L / 1.5 /
251519112 11Holes,R / 1.5 /
Navicular Locking Plate
HC 2.4/2.7
251520110 11Holes 5 1.5 57
Talus Neck Locking Plate
HC 2.4/2.7
251521060 6Holes 11 1.5 38.4
X-Type Locking Plate X
HC 2.4/2.7
251522010 4Holes (22*14) 14 1.5 22
251522020 4Holes (24*18) 18 1.5 24
251522030 4Holes (30*18) 20 1.5 30
251522040 4Holes (30*22) 20 2.5 36





*All the prices are only for reference. Exact price will be based on the latest quotation.
Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III
Pure Titanium Foot and Ankle Bone Fracture Calcaneal Locking Plate III

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed